English
Product
Contact us

 

VTWFA-3

product type:VTWFA-3

views:102

pdf:VTWFA-3.pdf

Next:VTWF-ED-R-2
Prev:VTWFA-1

Details

WIFI Antenna

Part NumberVTWFA-3

 

 


 

 

1 Dimension(Unit:mm)



2 Electrical Characteristics

2.1 Dielectric Antenna

Form 1

No.

Item

Specifications

Post Environmental Tolerance

1

FrequencyMHz

2400 MHz

2

Band WidthMHz

±100 MHz

3

V.S.W.Rin BW 

≤1.61

4

GainZenith

5dB

±0.5 dB

5

Polarization

Vertical

6

Impedance

50 Ω

2.2Mechanical

Form 2

No.

Item

Specification

1

Cable

2

Connector

SMA

3

Plastic Housing

Black

3  Reliability

ConditionTemperature: 40±5℃ 

Load: DC=5V±0.5 V 

Quantity: 2000pcs 

Sustained Time: 480h 

4 Environmental Specifications

Condition

Post Environmental Tolerance (Refer to the form 1) 

Temperature range 25±3℃

Relative Humidity range 55~75%RH

Operating Temperature range -40℃~+85℃ 

Storage Temperature range -40℃~+100℃ 

5.1 Moisture Proof 

The device should satisfy the electrical characteristics specified in form 1 after exposed to the temperature 40±2℃and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under normal condition. 

5.2 Vibration Resist 

The device should satisfy the electrical characteristics specified in form 1 after applied to the vibration of 10 to 55Hz with amplitude of 1.5mm for 2 hours each in X ,Y and Z directions. 

5.3 Drop Shock 

The device should satisfy the electrical characteristics specified in form 1 after dropping onto the hard wooden board from the height of 30cm for 3 times each facet of the 3 dimensions of the device. 

5.4 High Temperature Endurance 

The device should satisfy the electrical characteristics specified in form 1 after exposed to temperature 80±5℃for 24±2 hours and 1~2 hours recovery time under normal temperature. 

5.5 Low Temperature Endurance 

The device should also satisfy the electrical characteristics specified in form 1 after exposed to the temperature -40℃±5℃for 24±2 hours and to 2 hours recovery time under normal temperature. 

5.6 Temperature Cycle Test 

The device should also satisfy the electrical characteristics specified in form 1 after exposed to the low temperature -25℃ and high temperature +85℃ for 30±2 min each by 5 cycles and 1 to 2 hours recovery time under normal temperature.